Sale!

High Temperature Industrial Humidity Probe | RMS-HCD-IC102

$ 92.87

You save:

Description High Temperature Industrial Humidity Probe | RMS-HCD-IC102 Probe type Digital standard probe Humidity sensor Hygromer HT-1 Temperature sensor PT100 1/3 DIN Class B Long-term stability <1 %rh / year Accuracy w. adjustment profile “standard” at 23 °C / 10, 35, 80 %rh ± 0.8 %rh / ± 0.1 K Reproducibility Airchip <0.02 %rh / 0.01 K Response time t 63 <15 s, without filter Power consumption 3.3…5.5 VDC Dimensions Ø15 x 144 mm Sensor Head Ø15 x 111 mm Electronic Operating range -100…200 °C / 0…100 %rh Allowed wind speed 20 m/s, with filter Exploitation software RMS-Config / RMS Server Software / RMS Cloud Psychrometric calculations Dew or frost point Software Update Via RMS-Config / RMS Server Software / RMS Cloud Digital output signal (standard) UART FDA/GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible Probe adjustment by software 1 Point & multipoint %rh & °C Reverse voltage protection Mechanically in the connector Max. cable length <3 m Probe protection Filter carrier, brass nickel-plated Filter cartridge depending on the application, order separately Weight 376 g Housing Polycarbonate Current consumption <0.5 mA @ 2.5…5.5 VDC Filter type No filter Protocols Modbus RTU High Temperature Industrial Humidity Probe | RMS-HCD-IC102